Enclosed Switching Power Supply, Mean Well LRS-600 size drawing (PDF)

Datasheet — Enclosed Switching Power Supply, Mean Well LRS-600 by Milo

Open the PDF
Enclosed Switching Power Supply, Mean Well LRS-600Get the CAD modelEnclosed Switching Power Supply, Mean Well LRS-600CC-PSULRS-SZ-lrs-600.pdf

Text of this datasheet

Mean Well LRS enclosed power supply, LRS-600

Size drawing - LRS-600 values on the views - terminal end at the left, as Mean Well draws it - scale 1:4

Sym. Dimensi LRS-600

Terminal end

Length 225 xs = 26.7 Width 124 Height 41 General tolerance,

Bottom holes’ thread, M

Bottom holes, count

Bottom holes, depth L

Bottom holes from the terminal end

L=225 Bottom holes apart, along Bottom holes from the front face

ns = 8,ds=4,ts=6,fs=2

Bottom holes apart, across

wsl = 2.5. hsl = 6.9 Side holes' thread, M 5, .

Side holes, count zsl = 13.3, esl = 5.2 Side hole faces (2: both long sides) Side holes, depth L

Side holes from the terminal end Side hole columns apart

First column's lowest hole, height

Fan grille (illustrative) Holes up a column, apart

Side slot width

Side slot height Side slot bottom, height Side slot from its hole, terminal side Terminal pitch Terminal opening O Terminals, count L Fan centre to the far end's inside face

xb = 33.5 pxb = 150 Fan centre from the back face

Last side holes to the far end (recorded)

nb = 4, db = 4, tb =3 Tab holes span (recorded) 1 ,

Tab width (recorded)

Tab reach (recorded) Source levels

Main value = the modeled value (nominal, else the middle of min-max). Grey under a value = its min-max, where the source gives both. Tab pitch (recorded) < / = = the source gives only that limit, modeled at it. ref = reference.

L2 = the standard itself (or its complete free preview, or the maker's drawing). L1 = two or more independent sources agree: the release gate.

LO = one source only: printed amber and marked *.

c = a source value was corrected; the datasheet says how.

House convention = a detail no source dimensions, drawn to a stated house rule. '? CommunityCAD Size drawing LRS-600 '

This size's values: L2 34. Notes STANDARDS FOLLOWED FAMILY / DETAIL

No published standard: Mean Well's datasheet drawing of each model Mean Well LRS enclosed power supply - LRS-600

Tab station (recorded)

Lead-in @, 90° (house: D + P)

TITLE

CommunityCAD's model from Mean Well's published drawing; not a Mean Well file (ADR 0141). Tapped holes: thread to the drawing's L, then a 118° drill point; dl is a house lead-in. SHEET REV SCALE PROJECTION UNITS

(recorded): on the drawing, in the data, not modeled (tabs, notch and chains to it). CC-PSULRS-SZ-1Lrs-600 A 1:4 Dimensions in mm

xf is measured to the far end plate's inside face; it places the illustrative grille. SPEC VERSION LICENSE PAGE Side slots (wsl x hsl): either side of each column's lowest side hole. cfd05b053c736a4f15ba3030aa41febd40cdc205 CC-BY 4.0 IronPixel Labs LLC 1/1 Not drawn on the sheets (house style, sheet DO2): perforation, vents, screws, label, mark.

Modeled from cited sources; not certified. Found an error? Use the feedback section on the part page.