CR123A Battery, IEC 60086
At 16 to 17 mm across and 33.5 to 34.5 mm long, the CR123A battery (IEC 60086) is drawn here as simplified STEP files.

How these parts are made, and what the levels mean: read the method
- Also known as: CR123A cylindrical cell, CR123A primary cell
- Model id:
iec60086-cr123a
- Standard: IEC 60086 · size CR123A
Files
| Part key | Simplified |
|---|
iec60086-cr123a | STEP |
Dimensions

| Symbol | Name | min | nom | max | Modeled | Rule | Level |
|---|
| d | Diameter | 16 | | 17 | 16.5 | midpoint of min–max | L1 |
| h | Overall height | 33.5 | | 34.5 | 34 | midpoint of min–max | L1 |
| d_pos | Positive contact diameter | | | 9.6 | 9.6 | single limit (max), modeled at the limit | L1 |
| h_pos | Positive contact projection | 1 | | | 1 | single limit (min), modeled at the limit | L1 |
| d_neg | Negative contact diameter | 11 | | | 11 | single limit (min), modeled at the limit | L1 |
| e_neg | Negative contact recess | 0.5 | | 0.9 | 0.7 | midpoint of min–max | L1 |
Drawing

As a PDF: CC-IEC60086-SZ-CR123A.pdf.
From the maker's datasheet
As written on the ENERGIZER 123 datasheet (energizer-123), the maker's typical values for one product, not the standard's limits.
- Classification: "Lithium"
- Chemical System: Lithium / Manganese Dioxide (Li/MnO2)
- Designation: ANSI-5018LC, IEC-CR17345
- Nominal Voltage: 3.0 Volts
- Typical Capacity: 1500 mAh (to 2.0 volts)
- Typical Weight: 16.5 grams (0.58 oz.)
The CR123A battery beside the CR2
The CR123A is the last of the 11 IEC 60086 batteries published here, listed from AAAA to CR123A.
- Diameter (d): 16 to 17 mm on the CR123A battery, against 15 to 15.6 mm on the CR2.
- Overall height (h): 33.5 to 34.5 mm on the CR123A battery, against up to 27 mm on the CR2.
- Positive contact diameter (d_pos): up to 9.6 mm on the CR123A battery, against up to 7 mm on the CR2.
- Positive contact projection (h_pos): at least 1 mm on the CR123A battery, against at least 0.6 mm on the CR2.
Other sizes
Conventions
- Simplified only: four solids, the can, the wrap, the ring and the logo. STEP AP214, millimetres, Z along the axis, negative end at Z = 0, positive end toward +Z.
- No IEC 60086 edition is read: each size is the envelope of the makers' datasheets (Energizer, VARTA, Duracell), one lineage per maker.
- Disagreeing limits take the widest band the makers allow; a limit only one maker states is left open and the other bound is modeled as a single limit.
Documents
Sources
duracell-cr123, energizer-123, varta-6205. Full citations: the method page and this size's datasheet.
Found an error? Use the feedback section on this page.
Comments
Sign in to leave a comment.
Loading comments...