A27 Battery (Cylindrical Cell), IEC 60086

STEP Supports CommunityCAD0 downloads
A27 Battery (Cylindrical Cell), IEC 60086
1 / 6

A27 Battery (Cylindrical Cell), IEC 60086

At 7.4 to 8 mm across and 27 to 28.2 mm long, the A27 battery (IEC 60086) is drawn here as simplified STEP files.

A27 battery, IEC 60086

How these parts are made, and what the levels mean: read the method

  • Also searched as: A27 battery
  • Model id: iec60086-a27
  • Standard: IEC 60086 · size A27

Files

Part keySimplified
iec60086-a27STEP

Dimensions

Dimension symbols for A27 batteries (IEC 60086)

SymbolNameminnommaxModeledRuleLevel
dDiameter7.487.7midpoint of min–maxL1
hOverall height2728.227.6midpoint of min–maxL1
d_posPositive contact diameter3.24.23.7midpoint of min–maxL1
h_posPositive contact projection0.40.4single limit (min), modeled at the limitL1
d_negNegative contact diameter3.44.43.9midpoint of min–maxL1
e_negNegative contact recess0.30.3single limit (max), modeled at the limitL0 (max: one source)
p_negNegative contact projection0.30.3single limit (max), modeled at the limitL0 (max: one source)

Drawing

Drawing of the A27 battery with its values (IEC 60086)

As a PDF: CC-IEC60086-SZ-A27.pdf.

From the maker's datasheet

As written on the ENERGIZER A27 datasheet (energizer-a27), the maker's typical values for one product, not the standard's limits.

  • Classification: "Miniature Alkaline"
  • Chemical System: Manganese Dioxide (MnO2)
  • Designation: N/A
  • Nominal Voltage: 12.0 volts
  • Typical Capacity: 22 mAh to 6.0 volts
  • Typical Weight: 4.4 grams (0.2 oz)

The A27 battery beside the A23 and the 4LR44

The A27 is number 8 of the 11 IEC 60086 batteries published here, listed from AAAA to CR123A.

  • Diameter (d): 7.4 to 8 mm on the A27 battery, against 9.7 to 10.3 mm on the A23 and 12 to 13 mm on the 4LR44.
  • Overall height (h): 27 to 28.2 mm on the A27 battery, against 27.5 to 28.5 mm on the A23 and 23.9 to 25.2 mm on the 4LR44.
  • Positive contact diameter (d_pos): 3.2 to 4.2 mm on the A27 battery, against 3.5 to 6 mm on the A23 and at least 5 mm on the 4LR44.
  • Positive contact projection (h_pos): at least 0.4 mm on the A27 battery, against at least 0.43 mm on the A23 and at least 0.7 mm on the 4LR44.
  • Negative contact diameter (d_neg): 3.4 to 4.4 mm on the A27 battery, against at least 4.7 mm on the A23 and 5 to 6.6 mm on the 4LR44.
  • Negative contact recess (e_neg): up to 0.3 mm on the A27 battery, against 0.2 to 0.3 mm on the A23.
  • Negative contact projection (p_neg): up to 0.3 mm on the A27 battery, against up to 0.4 mm on the A23.

Other sizes

Documents

Sources

duracell-mn27, energizer-a27, varta-4227. Full citations: the method page and this size's datasheet.

Found an error? Use the feedback section on this page.

Comments

Sign in to leave a comment.

Loading comments...

From the datasheet

docs/CC-IEC60086-DS-A27.pdf

* CC-IEC60086-DS-A27 revA '?) CommunityCAD Size datasheet - A27 A27 battery Size datasheet: this size's values with their levels, conventions and sources. Envelope 7.7 x 27.6 mm (modeled) Part key iec60086-a27 Files 1 STEP AP214 (simplified) A27, side, 0.75:1 A27, from above, 3:1 Sym. Dimension…

View full datasheet →

docs/CC-IEC60086-SZ-A27.pdf

IEC 60086 cylindrical primary battery, A27 Size drawing - A27 values on the views - enlarged 5:1 Sym. Dimension A 7.70 7.40-8.0 Body diameter 27.6 Overall height 27.0-28.2 3.70 d_pos Positive contact diameter 3.20-4.2 h_pos Positive contact height Joe 3.9 d_neg Negative contact diameter e_neg…

View full datasheet →