docs/CC-IEC60086-SZ-A23.pdf

Datasheet — A23 Battery (Cylindrical Cell), IEC 60086 by Milo

IEC 60086 cylindrical primary battery, A23

Size drawing - A23 values on the views - enlarged 5:1

Sym. Dimension A23

10.00 9.70-10.30

Body diameter

28.00

Overall height 27.50-28.50

4.75

d_pos Positive contact diameter

h_pos 2 0.43 h_pos Positive contact height

d_neg Negative contact diameter

0.25

e_neg Negative contact recess 0.20-8.30

Source levels

Main value = the modeled value (nominal, else the middle of min-max).

Grey under a value = its min-max, where the source gives both.

H < / = = the source gives only that limit, modeled at it. ref = reference.

L2 = the standard itself (or its complete free preview, or the maker's drawing).

L1 = two or more independent sources agree: the release gate.

LO = one source only: printed amber and marked *.

c = a source value was corrected; the datasheet says how.

House convention = a detail no source dimensions, drawn to a stated house rule.

| d = 10.00 9.70-10.30

h = 28.00

27.50-28.50 This size's values: L16 - LO 1.

Notes

No IEC 60086 edition is read: the values are the makers' datasheets, reconciled (ADR 0034). The negative end is modeled flush unless e_neg has both limits (sheet D0O2).

Left open (ADR 0073): h_pos max, d_neg max.

Lt

d_neg 2 4.7

d = 10.00 9.70-10.30

TITLE

'? CommunityCAD Size drawing, A23

STANDARDS FOLLOWED FAMILY / DETAIL

IEC 60086 (no edition read: makers' datasheets) Cylindrical battery - A23

SHEET REV SCALE PROJECTION UNITS CC-IEC60086-SZ-A23 A 5:11 € Dimensions in mm SPEC VERSION LICENSE PAGE c59Ffdebeb44F40d327cd99112104ee541c4493d4 CC-BY 4.0 IronPixel Labs LLC 1/1

Modeled from cited sources; not certified. Found an error? Use the feedback section on the part page.