IEC 60086 cylindrical primary battery, A23
Size drawing - A23 values on the views - enlarged 5:1
Sym. Dimension A23
10.00 9.70-10.30
Body diameter
28.00
Overall height 27.50-28.50
4.75
d_pos Positive contact diameter
h_pos 2 0.43 h_pos Positive contact height
d_neg Negative contact diameter
0.25
e_neg Negative contact recess 0.20-8.30
Source levels
Main value = the modeled value (nominal, else the middle of min-max).
Grey under a value = its min-max, where the source gives both.
H < / = = the source gives only that limit, modeled at it. ref = reference.
L2 = the standard itself (or its complete free preview, or the maker's drawing).
L1 = two or more independent sources agree: the release gate.
LO = one source only: printed amber and marked *.
c = a source value was corrected; the datasheet says how.
House convention = a detail no source dimensions, drawn to a stated house rule.
| d = 10.00 9.70-10.30
h = 28.00
27.50-28.50 This size's values: L16 - LO 1.
Notes
No IEC 60086 edition is read: the values are the makers' datasheets, reconciled (ADR 0034). The negative end is modeled flush unless e_neg has both limits (sheet D0O2).
Left open (ADR 0073): h_pos max, d_neg max.
Lt
d_neg 2 4.7
d = 10.00 9.70-10.30
TITLE
'? CommunityCAD Size drawing, A23
STANDARDS FOLLOWED FAMILY / DETAIL
IEC 60086 (no edition read: makers' datasheets) Cylindrical battery - A23
SHEET REV SCALE PROJECTION UNITS CC-IEC60086-SZ-A23 A 5:11 € Dimensions in mm SPEC VERSION LICENSE PAGE c59Ffdebeb44F40d327cd99112104ee541c4493d4 CC-BY 4.0 IronPixel Labs LLC 1/1
Modeled from cited sources; not certified. Found an error? Use the feedback section on the part page.