92x38 AC Cooling Fan, Axial datasheet (PDF)

Datasheet — 92x38 AC Cooling Fan, Axial by Milo

Open the PDF
92x38 AC Cooling Fan, AxialGet the CAD model92x38 AC Cooling Fan, AxialCC-ACFAN-DS-92x38.pdf

Text of this datasheet

'?) CommunityCAD

CC-ACFAN-DS-92x38 rev A Size datasheet - 92x38

92x38 AC axial fan

Size datasheet: this frame's values with their levels, conventions and sources. Blades are illustrative, not any maker's design; frame, mounting holes and outline are from maker drawings.

Frame

Mounting holes

Connection

92x38, front face, 0.25:1 92x38, side view, 0.4:1 Frame material

Part key

Files

Sym. Dimension

a Frame side

t Frame thickness

e Hole spacing

dh Hole diameter

k Flange thickness (open corners) w Width across flats (round frame) dv Venturi (makers', not modeled)

92 mm square, 38 mm thick

4 x @4.2 through t, in two flanges k = 6.3 mm (house value, illustrative: no maker dimensions it)

lead wires or terminal tabs, by model (not modeled)

die-cast aluminium (drawn matte black)

fans-ac-axial-92x38 1 STEP AP214 (simplified)

Value Level 92 La -2 38 La - 2 82.5 l1-2 4.2 La 2

Modeled value: the nominal. * amber: one source (LO). c: a source value was corrected. - : not dimensioned by the makers (k: the house flange,

see Mounting holes). Level - independent sources.

No published standard (makers' drawings)

Page 1/2

AC axial fan - 92x38 - Dimensions in mm - CC-BY 4.0, IronPixel Labs LLC spec 304229b833a653b73db51178a38d40486ee7c36b

Modeled from cited sources; not certified. Found an error? Use the feedback section on the part page.

---

* CC-ACFAN-DS-92x38 rev A '?) CommunityCAD Size datasheet - 92x38

Conventions

Illustrative rotor: Venturi bore s - (a - e)/2, s the smallest outside width (a, or w on the round frame), hub, four struts at the outlet face and swept blades, as the DC fans. Blades are illustrative, not any maker's design; frame, mounting holes and outline are from maker drawings.

« Frame sides: Open between two flanges k thick, one at each face; each hole runs through both. Where no drawing tolerances k, k is the house flange t/6 (to 0.1 mm, at least 1.5 mm), labelled (house).

« Mounting holes: Square frames: four through holes dh on a square of side e. Round frame: circle a cut by flats w apart, two holes dh e apart on the horizontal centreline.

« Values: Reconciled from two or more makers' drawings; where they differ on a, w or dh, the largest stated, so every maker's frame fits. dv is recorded, not modeled.

e Connection, labels: Lead wires or terminal tabs by model, neither modeled; no labels or arrows. Die-cast aluminium frame, drawn matte black. Intake at +Z, airflow toward -Z.

Sources

Source Publisher Retrieved 256

mechatronics-ac-axial Mechatronics Fan Group 2026-10-29 7ab9ddfééeb3 (kept outside the repo) orion-ac-axial Orion Fans (Knight Electronics, Inc.) 2026-10-29 dee795d93132 (kept outside the repo)

The whole series (verification map, corrections, drawings): CC-ACFAN-DS.

No published standard (makers' drawings) Page 2/2 AC axial fan - 92x38 - Dimensions in mm - CC-BY 4.0, IronPixel Labs LLC spec 304229b833a653b73db51178a38d40486ee7c36b

Modeled from cited sources; not certified. Found an error? Use the feedback section on the part page.