Wire fan guard, square DC axial fans, 60
Size drawing - 60 values on the views - enlarged 2:1
Sym. Dimensi
Hole spacing
dh Hole diameter (eyelet inside)
Outside ring diameter
Height
dring Ring wire diameter
drib — Rib wire diameter
dring = 1.6
Source levels
Main value = the modeled value (nominal, else the middle of min-max).
Grey under a value = its min-max, where the source gives both.
< / = = the source gives only that limit, modeled at it. ref = reference.
L2 = the standard itself (or its complete free preview, or the maker's drawing).
L1 = two or more independent sources agree: the release gate.
LO = one source only: printed amber and marked *.
c = a source value was corrected; the datasheet says how.
House convention = a detail no source dimensions, drawn to a stated house rule.
This size's values: L15 - LO 1.
Notes
No published standard: values are reconciled from makers' drawings (ADR 0034). D, h and the wire sizes: the largest any maker states where they differ (ADR 0091). Rings, ribs and eyelet loops are illustrative: sheet DO2.
4 rings at pitch p = 6.45 mm (house rule, gap < 6.35 mm; sheet DO2).
drib = 1.6*
TITLE
'? CommunityCAD Size drawing, 60
STANDARDS FOLLOWED FAMILY / DETAIL
No published standard (makers' drawings) Wire fan guard - 60
SHEET REV SCALE PROJECTION UNITS CC-FANGUARD-SZ-60 A 2:1 € Dimensions in mm SPEC VERSION LICENSE PAGE a6ce283c84109cF9cC954863c229586eb671d04c CC-BY 4.0 IronPixel Labs LLC 1/1
Modeled from cited sources; not certified. Found an error? Use the feedback section on the part page.