docs/CC-FANGUARD-SZ-30.pdf

Datasheet — 30 Fan Guard (Fan Grill), Wire fan guard by Milo

Wire fan guard, square DC axial fans, 30

Size drawing - 30 values on the views - enlarged 2:1

Sym. Dimensi

Hole spacing

dh Hole diameter (eyelet inside)

Outside ring diameter

Height

dring = 1.6* . dring Ring wire diameter

drib — Rib wire diameter

Source levels

Main value = the modeled value (nominal, else the middle of min-max).

Grey under a value = its min-max, where the source gives both.

< / = = the source gives only that limit, modeled at it. ref = reference.

L2 = the standard itself (or its complete free preview, or the maker's drawing). L1 = two or more independent sources agree: the release gate.

LO = one source only: printed amber and marked *.

drib = 1.6* c = asource value was corrected; the datasheet says how.

House convention = a detail no source dimensions, drawn to a stated house rule. This size's values: L13 - LO 3.

Notes

No published standard: values are reconciled from makers' drawings (ADR 0034). D, h and the wire sizes: the largest any maker states where they differ (ADR 0091). Rings, ribs and eyelet loops are illustrative: sheet DO2.

2 rings at pitch p = 5.05 mm (house rule, gap < 6.35 mm; sheet DO2).

TITLE

'? CommunityCAD Size drawing, 30

STANDARDS FOLLOWED FAMILY / DETAIL

No published standard (makers' drawings) Wire fan guard - 30

SHEET REV SCALE PROJECTION UNITS CC-FANGUARD-SZ-30 A 2:1 € Dimensions in mm SPEC VERSION LICENSE PAGE a6ce283c84109cF9CC954863c229586eb671d04c CC-BY 4.0 IronPixel Labs LLC 1/1

Modeled from cited sources; not certified. Found an error? Use the feedback section on the part page.

Original PDF