docs/CC-ACFAN-DS-172x150x51.pdf

Datasheet — 172x150x51 AC Cooling Fan (Mains Fan), AC axial fan by Milo

CC-ACFAN-DS-172x150x51 rev A Size datasheet - 172x150x51

'?) CommunityCAD

172x150x51 AC axial fan

Size datasheet: this frame's values with their levels, conventions and sources. Blades are illustrative, not any maker's design; frame, mounting holes and outline are from maker drawings.

Frame round, 172 mm with flats 150 mm apart, 51 mm thick

Mounting 2 x @4.5 through t, in two

holes flanges k = 8.5 mm (house

value, illustrative: no maker dimensions it)

Connection _ lead wires or terminal tabs, by

172x150x51, front face, 0.15:1 172x150x51, side view, 0.2:1 model (not modeled)

Frame die-cast aluminium (drawn material matte black) Part key fans-ac-axial-172x150x51 Files 1 STEP AP214 (simplified)

Sym. Dimension Value Level

a Frame side 171.5 1-3

t Frame thickness 51 l1- 3

e Hole spacing 162 l1- 3

dh Hole diameter 4.5 l1- 3

k Flange thickness (open corners) - -

w Width across flats (round frame) 151 l1- 3

dv Venturi (makers', not modeled) - -

Modeled value: the nominal. * amber: one source (LO). c: a source value was corrected. - : not dimensioned by the makers (k: the house flange, see Mounting holes). Level - independent sources.

No published standard (makers' drawings) Page 1/2 AC axial fan - 172x150x51 - Dimensions in mm - CC-BY 4.0, IronPixel Labs LLC spec 54a208abf031c40a10474bfF4c55152d66ee5412

Modeled from cited sources; not certified. Found an error? Use the feedback section on the part page.

---

CC-ACFAN-DS-172x150x51 rev A Size datasheet - 172x150x51

'?) CommunityCAD

Conventions

Illustrative rotor: Venturi bore s - (a - e)/2, s the smallest outside width (a, or w on the round frame), hub, four struts at the outlet face and swept blades, as the DC fans. Blades are illustrative, not any maker's design; frame, mounting holes and outline are from maker drawings.

« Frame sides: Open between two flanges k thick, one at each face; each hole runs through both. Where no drawing tolerances k, k is the house flange t/6 (to 0.1 mm, at least 1.5 mm), labelled (house).

« Mounting holes: Square frames: four through holes dh on a square of side e. Round frame: circle a cut by flats w apart, two holes dh e apart on the horizontal centreline.

« Values: Reconciled from two or more makers' drawings; where they differ on a, w or dh, the largest stated, so every maker's frame fits. dv is recorded, not modeled.

e Connection, labels: Lead wires or terminal tabs by model, neither modeled; no labels or arrows. Die-cast aluminium frame, drawn matte black. Intake at +Z, airflow toward -Z.

Sources

Source Publisher Retrieved sha256

mechatronics-ac-axial Mechatronics Fan Group 2026-10-29 Jab9ddfé6eb3 (kept outside the repo) sunon-ac-fan-2011 Sunon 2026-10-29 483e6618afa8 (kept outside the repo) orion-ac-axial Orion Fans (Knight Electronics, Inc.) 2026-10-29 dee795d93132 (kept outside the repo)

The whole series (verification map, corrections, drawings): CC-ACFAN-DS.

No published standard (makers' drawings) Page 2/2 AC axial fan - 172x150x51 - Dimensions in mm - CC-BY 4.0, IronPixel Labs LLC spec 54a208abf031c40a10474bfF4c55152d66ee5412

Modeled from cited sources; not certified. Found an error? Use the feedback section on the part page.

Original PDF